|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Hi-Reliability Evacuated Miniature Crystal Oscillator EX-209 EX-209 Features * * * * * 16 pin Double Dip Package Ruggedized hybrid thick film construction Low Power Consumption Frequency Range: 10 MHZ to 40 MHZ Previous Model: EX-245 Applications * Severe Environmental Conditions Performance Specifications Parameter Min Typ Max Units Condition Frequency Stabilities1 [10 to 20 MHz] vs. operating temperature range (referenced to +25C) Initial tolerance for fixed frequency Settability vs. supply voltage change vs. load change vs. aging / day vs. aging / 1 year vs. aging / 10 year (10 to <12 MHz) vs. aging / 10 year (12 to <16 MHz) vs. aging / 10 year (16 to 20 MHz) Warm-up Time2 -50 -75 -100 -1.0 -0.2 -15 -15 -2 -200 -1000 -1500 -2000 +50 +75 +100 +1.0 +0.2 +15 +15 +2 +200 +1000 +1500 +2000 120 180 ppb ppb ppb ppm ppm ppb ppb ppb ppb ppb ppb ppb seconds seconds 0... +60C -20... +70C -40... +85C fixed, no adjust VS 5% Load 5% after 7 days of operation to 1ppm of final freq. @+25C to 100ppb of final freq. @+25C Frequency Stabilities1 [>20 to 40 MHz] vs. operating temperature range (referenced to +25C) -75 -100 -150 +75 +100 -150 ppb ppb ppb 0... +60C -20... +70C -40... +85C Vectron International * 267 Lowell Road, Hudson, NH 03051 * Tel: 1-88-VECTRON-1 * http://www.vectron.com Performance Specifications Parameter Initial tolerance for fixed frequency Settability vs. supply voltage change vs. load change vs. aging / day vs. aging / 1 year vs. aging / 10 year Warm-up Time2 Min -1.5 -0.3 -25 -25 -3 -300 -3000 Typ Max +1.5 +0.3 +25 +25 +3 +300 +3000 120 180 Units ppm ppm ppb ppb ppb ppb ppb seconds seconds VDC Watts Watts Watts Condition fixed, no adjust VS 5% Load 5% after 7 days of operation to 1ppm of final freq. @+25C to 100ppb of final freq. @+25C Supply Voltage (Vs) Supply voltage (Standard) Power Consumption 4.75 5.0 5.25 2.2 0.7 1.2 during warm-up steady state @ +25C steady state @ -40C RF Output Signal [Standard] Load Signal Level (Vol) Signal Level (Voh) Rise/Fall Time Duty cycle Signal [Option] Load Output Power (Standard) Output Power (Option) Harmonics Spurious 0.0 +3.0 50 +2.0 +5.0 +4.0 +7.0 -25 -60 40 0.9 +7 60 Sinewave ohm dBm dBm dBc dBc 50 ohm load 50 ohm load 15 0.1 HCMOS pF Vdd Vdd ns % (10-90%) (Voh-Vol)/2 Frequency Tuning (EFC) Tuning Range Tuning Range Vref Phase Noise (10 to 20 MHZ) 3 Fixed OCXO; No adjust Sufficient to compensate for 10 years aging +4.0 +4.1 +4.2 1 EFC (0V to 4V) source current 1 mA maximum VDC Additional Parameters [10 to 20 MHz] -100 -125 -140 -145 -145 -90 -115 -130 -140 -140 1 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz ppb/g 10 Hz 100 Hz 1 kHz 10 kHz 10 kHz 10 Hz 100 Hz 1 kHz 10 kHz 10 kHz Test at 10g sine vibration at 100Hz Phase Noise3 (>20 to 40 MHZ) G-Sensitivity Vectron International * 267 Lowell Road, Hudson, NH 03051 * Tel: 1-88-VECTRON-1 * http://www.vectron.com Performance Specifications Parameter * Radiation Tolerant (operating): * Mechanical Shock (survive)***: * Vibration Random (survive)***: * Vibration Sine (survive)***: Note: *** Met by design, not tested Min Typ Max Units Condition Environmental Conditions (Designed to meet) Active devices are selected from a family of product that is inherently radiation tolerant to meet 100krad (SI) total dose MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec) MIL-STD-202, Test Method 214, Condition I-F (20Grms, 3 minutes/axis) MIL-STD-202, Test Method 204, Condition D (20Grms, 20 minutes/axis) Screening Options Ordering Code Test Inspection Nondestructive Bond Pull Internal Visual Per Mil-PRF55310 Requirement Stabilization Bake S-Level Screening MIL-STD-883 Method 2023 Internal Visual Per Mil-PRF-55310 Requirement MIL-STD-883 Method 1008, Condition C MIL-STD-883 Method 1011, Condition A MIL-STD-883 Method 1010, Condition A MIL-STD-883 Method 2001 MIL-STD-883 Method 2020, Condition B 85C (2) for 240hrs MIL-STD-883 Method 2012 150C for 48hrs S B-Level Screening N/A Internal Visual Per Mil-PRF-55310 Requirement MIL-STD-883 Method 1008, Condition C N/A 150C for 48hrs B Thermal Shock 0C to 100C for 15cycles -55C to 85C (2) for 10cycles 1000g's (3) Y1 Only 10g peak at 60Hz minimum Temperature Cycling (1) MIL-STD-883 Method 1010, Condition A MIL-STD-883 Method 2001 N/A -55C to 85C (2) for 10cycles 1000g's (3) Y1 Only Constant Acceleration (1) PIND Electrical Test Burn-in (1) Radiographic Per Mil-PRF-55310 Requirement Per Mil-PRF-55310 Requirement 85C (2) for 240hrs N/A Note: (1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310. (2) The maximum operating and storage temperature of the EX-209 is +85C. The EX-209 shall not be exposed to temperature higher than +85C at length of time. (3) The design and construction of the EX-209 can withstand up to 1000g's constant acceleration Vectron International * 267 Lowell Road, Hudson, NH 03051 * Tel: 1-88-VECTRON-1 * http://www.vectron.com Outline Drawing / Enclosure Dimensions in inches (mm) Type A Code 0 Height "H" 0.35 (8.9 mm) Pin Length "L" 0.17 Pin Connections 1 2-4 8 9 13-14 15 16 EFC \ No Connect No Connect Ground (Case) Output No Connect Vref \ No Connect Supply Voltage Input Recommended Reflow Profile 220 TEMPERATURE (oC) 183 150 60s 60-90s 45-60s TIME (s) Vectron International * 267 Lowell Road, Hudson, NH 03051 * Tel: 1-88-VECTRON-1 * http://www.vectron.com Ordering Information EX - 209 0 - D A J - 002S - 10M0000000 Product Family EX: EMXO Package 25 x 25 mm Height 0: A0.35" Supply Voltage D: 5 Vdc RF Output Code A: HCMOS E: Sinewave Temperature Range E: -40C to +85C J: -20C to +70C S: 0C to +60C Frequency Platform Code Tuning Option (1st digit): 0: Fixed Frequecy 1: Electrical Tuning Output Power (2nd digit) 0: 0 dBm 1: +3 dBm Stability Code (3rd digit) 0: 50ppb 1: 75ppb 2: 100ppb 3: 150ppb Screening Option (4th digit) S: "S" Level screening, Swept Quartz C: "B" Level screening, Swept Quartz B: "B" Level screening, Un-Swept Quartz E: "EM" Engineering Model , Un-Swept Quartz P: Proof of Design "POD-Prototype" , Un-Swept Quartz Notes: 1. Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies. 2. Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25C). 3. Phase noise degrades with increasing output frequency. 4. Subject to technical modification. 5. Contact factory for availability. For Additional Information, Please Contact Vectron International 267 Lowell Road Hudson, NH 03051 Tel: 1.888.328.7661 Fax: 1.888.329.8328 USA: Vectron International Landstrasse, D-74924 Neckarbischofsheim, Germany Tel: +49 (0) 3328.4784.17 Fax: +49 (0) 3328.4784.30 Europe: Vectron International 1F-2F, No 8 Workshop, No 308 Fenju Road WaiGaoQiao Free Trade Zone Pudong, Shanghai, China 200131 Tel: 86.21.5048.0777 Fax: 86.21.5048.1881 Asia: Disclaimer Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Rev: 5/7/2009 daf Vectron International * 267 Lowell Road, Hudson, NH 03051 * Tel: 1-88-VECTRON-1 * http://www.vectron.com |
Price & Availability of EX-2090-DAE-002S |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |